• GG01

    Gardon Gauge Water-Cooled High Heat Flux Sensor

    GG01 is a water-cooled sensor that measures heat flux. The Gardon gauge sensor is based on copper and copper alloys, and works at heat flux levels at which other sensors get toasted. Optionally GG01 can be equipped with a sapphire window; to measure radiative heat flux only, and not convective heat flux. GG01 has an on-board thermocouple type K and is available with various dedicated measurement ranges.
    • Withstands very high heat fluxes
    • Fast response time
    • Equipped with type K thermocouple to measure body temperature
    • Suitable for use in high vacuum
    • Safe storage with a practical protection cap
  • HFP01

    Heat Flux Plate

    HFP01 is the world’s most popular sensor for heat flux measurement in the soil as well as through walls and building envelopes. The total thermal resistance is kept small by using a ceramics-plastic composite body. The sensor is very robust and stable. It is suitable for long term use on one location as well as repeated installation when a measuring system is used at multiple locations. If measuring in soil, in case a more accurate measurement is needed the model HFP01SC should be considered.

    • Low thermal resistance (essential for use on walls and windows)
    • Large guard area (required by the ISO 9869 standard)
    • Low electrical resistance (low pickup of electrical noise)
    • High sensitivity (good signal to noise ratio in low-flux environments such as buildings)
    • Robustness, including a strong cable
    • IP protection class: IP67 (essential for outdoor application)
  • HFP01SC

    Self-Calibrating Heat Flux Sensor

    HFP01SC self-calibrating heat flux sensor™ is a heat flux sensor for use in the soil. It offers the best available accuracy and quality assurance of the measurement. The on-line self-test verifies the stable performance and good thermal contact of sensors that are buried and cannot be visually inspected and taken to the laboratory for recalibration. The self-test also includes self-calibration which compensates for measurement errors caused by the thermal conductivity of the surrounding soil (which varies with soil moisture content), for sensor non-stability and for temperature dependence.

    • Low thermal resistance
    • Large guard area (required by the ISO 9869 standard)
    • Low electrical resistance (low pickup of electrical noise)
    • High sensitivity (good signal to noise ratio in low-flux environments)
    • Robustness, including a strong cable (essential for permanently installed sensors)
    • IP protection class: IP67 (essential for outdoor application)
    • Incorporated film heater for self-testing
  • HFS01

    High Heat Flux Sensor for Concentrated Solar Radiation and Flames, Water Cooled

    HFS01 is a water-cooled sensor that measures high-level radiative and convective heat fluxes. It is designed for studies of concentrated solar irradiance (800 x concentrated direct solar radiation) and high-intensity flames (gas burners, coal fires). HFS01 has a very robust all-metal / ceramics instrument body and sensor, and is equipped with a high-temperature cable to survive the extreme conditions of a typical experiment.
    • Robust all-stainless steel body
    • High-temperature signal cable
    • Signal wires electrically insulated from the sensor body and from cooling water
  • SBG01

    Water Cooled Heat Flux Sensor

    SBG01 is a water-cooled sensor that measures heat flux. The ISO standards call this a heat flux meter. Introduced in 2008, SBG01 has rapidly become the sensor of choice for fire testing. SBG01 is mainly used to test reaction to fire and fire resistance. It is also used as a calibration reference standard for test equipment, for example in flammability and smoke chamber tests. SBG01 complies with the requirements of the most common ASTM and ISO standard test methods.
    • Robust and serviceable water tubes
    • Scratch resistant absorber coating (slightly lowered surface)
    • Safe storage with a practical protection cap
    • Durable cable with strain relief, temperature resistant up to 200 °C
  • TP08

    Small Size Non-Steady-State Probe for Thermal Conductivity Measurement

    TP08 is a probe that offers the possibility to perform a practical and fast measurement of the thermal conductivity (or thermal resistivity) of the medium in which it is inserted at a high accuracy level. It works in compliance with the ASTM D5334-14, D5930-97 and IEEE 442-1981 standards. The TP08 is a small version of type TP02, made for situations where the length of the TP02 poses a problem. The standard TP08 probe has proven its suitability for soils, thermal backfill materials, sediments, foodstuff, powders, sludges, paints, glues and various other materials.
    • The standard TP08 probe has proven its suitability for soils, thermal backfill materials, sediments, foodstuff, powders, sludges, paints, glues and various other materials.
    • Practical and fast measurement of the thermal conductivity (or thermal resistivity) of the medium in which it is inserted at a high accuracy level
  • TRSYS01

    High-accuracy thermal resistance measuring system with 2 measurement locations

    TRSYS01 is a high-accuracy system for on-site measurement of thermal resistance, R, thermal conductance, the Λ-value, and thermal transmittance, the U-value, of building envelopes. TRSYS01 is mostly used for measurements according to standard practices of ISO 9869 and ASTM C1155 / C1046. The system is equipped with high-accuracy electronics, two heat flux sensors of model HFP01 as well as two pairs of matched thermocouples. The two measurement locations provide redundancy, leading to a high level of confidence in the measurement result. The high accuracy of the heat flux sensors and temperature difference measurements ensures that TRSYS01 continues measuring when other systems no longer perform; in particular at very low temperature differences across the wall.
    • Temperature difference sensors: tested for 0.1 °C accuracy requirements
    • Superior heat flux sensor, stable: waterproof (IP67), corrosion-proof
    • Continues measuring when others give up: high sensitivity amplifier + high sensitivity sensors
  • TRSYS01 heat flux measuring system

    High-accuracy heat flux measuring system with 2 measurement locations

    TRSYS01 is a high-accuracy system for on-site measurement of thermal resistance, R, thermal conductance, the Λ-value, and thermal transmittance, the U-value, of building envelopes. TRSYS01 is mostly used for measurements according to standard practices of ISO 9869 and ASTM C1155 / C1046. The system is equipped with high-accuracy electronics, two heat flux sensors of model HFP01 as well as two pairs of matched thermocouples. The two measurement locations provide redundancy, leading to a high level of confidence in the measurement result. The high accuracy of the heat flux sensors and temperature difference measurements ensures that TRSYS01 continues measuring when other systems no longer perform; in particular at very low-temperature differences across the wall.
    • Temperature difference sensors: tested for 0.1 °C accuracy requirements
    • Superior heat flux sensor, stable: waterproof (IP67), corrosion-proof
    • Continues measuring when others give up: high sensitivity amplifier + high sensitivity sensors

Go to Top