SR20-D2

Digital Secondary Standard Pyranometer with Modbus RTU and 4-20 mA Output

SR20-D2 is a solar radiation sensor of the highest category in the ISO 9060 classification system: secondary standard. SR20-D2 is designed for the solar PV industry, offering two types of commonly used irradiance outputs: digital via Modbus RTU over RS-485 and analogue 4-20 mA (current loop). These industry standards allow for easy data acquisition, easy read-out and error-free instrument exchange, when using SR20-D2. Individually tested for temperature and directional response, SR20-D2 is the most accurate digital secondary standard pyranometer available.

  • Digital output: easy implementation & servicing
  • Best-in-class temperature response, < ± 0.4 % (-30 to +50 °C), best  “zero offset a” and best calibration uncertainty
  • Test certificates for temperature response and directional response included as required by ISO 9060
  • Re-calibration registers fully accessible to users

Description

Best Pyranometer for the PV Industry

SR20-D2 is the most accurate digital secondary standard pyranometer available. Its benefits:

  • Digital Output: Easy Implementation & Servicing
  • Best-in-class temperature response, < ± 0.4 % (-30 to +50 °C), best  “zero offset a” and best calibration uncertainty
  • Test certificates for temperature response and directional response included as required by ISO 9060
  • Re-calibration registers fully accessible to users

In order to improve overall measurement accuracy, Hukseflux effectively targeted two major sources of measurement uncertainty: calibration and “zero offset a”.
In addition, SR20-D2 has a negligible temperature response. All are best in class. The temperature response of every individual instrument is tested and corrected onboard by the instrument electronics, using a second degree polynomial. SR20-D2’s low temperature dependence makes it the ideal candidate for use under very cold and very hot conditions.

SR20-D2 Pyranometer Design

The pyranometer employs a state-of-the-art thermopile sensor with black coated surface, two domes and an anodised aluminium body. The connector, desiccant holder and sun screen fixation are very robust and designed for long term industrial use. SR20-D2 uses a high-end 24-bit A/D converter. All parts are specified for use across SR20-D2’s entire rated operating temperature range. SR20-D2 offers two types of outputs commonly used in the solar PV industry: digital output via Modbus RTU over 2-wire RS-485 and analogue 4-20 mA output (current loop).

Suggested Use

  • PV system performance monitoring
  • All networks with regular instrument exchange
  • Scientific meteorological observations
  • Reference instrument for comparison
  • Extreme climates (tropical / polar)

Areas of Application

  • Meteorology / surface energy flux measurement
  • Solar energy / PV system performance monitoring

Accessories

  • VU01
  • AMF02
  • SHR02
  • PMF01
  • PMF02
  • VMA01

Specifications

Measurand

Hemispherical solar radiation

Application

PV monitoring commercial and utility scale, PV monitoring small sized, meteorology / climatology, other

ISO 9060:2018 classification

Spectrally flat Class A (secondary standard)

IEC 61724-1:2017 compliance

Class A (when used with VU01)

Calibration uncertainty

< 1.2 % (k = 2)

Zero offset a

5 W/m² unventilated and 2.5 W/m² ventilated

Calibration traceability

to WRR

Calibration registers

Accessible to users

Spectral range

285 to 3000 x 10⁻⁹ m

Rated operating temperature range

-40 to +80 °C

Temperature response

<± 0.4 % (-30 to +50 °C)

Heater

no heating

Temperature response test of individual instrument

report included

Directional response test of individual instrument

report included

Standard cable length

5 m

Backwards compatibility

SR20-D1

Communication protocol

Modbus / over 2-wire RS-485

Transmission mode

RTU

Rated operating voltage range

5 to 30 VDC

Power consumption

< 75 x 10⁻³ W at 12 VDC

4-20 mA output

:

Output

irradiance in W/m²

Transmitted range of 4-20 mA output

0 to 1600 W/m2

Rated operating voltage range of 4-20 mA output

5.5 to 40 VDC

main supply

< 75 x 10⁻³ W

-4-20 mA current loop

< 40 x 10⁻³ W at 12 VDC

Options

Longer cable, in multiples of 5 metres
Adapted transmitted range for 4-20 mA output
Ventilated with VU01 ventilation unit

Downloads

Download Product Brochure

Download Product Manual